AUTHORS: R. Hilton and S.Dudkiewicz, Maury Microwave Corp
PUBLICATION HISTORY: MICROWAVE JOURNAL – JUNE 2018
ABSTRACT: This paper reviews the challenges of on-wafer load pull measurements at 5G mmW bands, specifically how high insertion losses can reduce the effectiveness of load pull and how to overcome these losses through the novel concept of hybrid-active load pull.