Home < RFDCS Products < Automated Tuner Controller MT986C Series

Automated Tuner Controller

MT986C Series

The Maury MT986C automated tuner controller provides comprehensive control of up to four automated microwave tuner assemblies in manual mode or automated mode. Manual control is exercised via the controller front panel keypad, manual position knob and other front panel swithches. The controller provides automatic control using an external host computer, and is primarily intended for operation under remote control from the host computer via an IEEE-488 General Purpose Interface Bus (GPIB). In this mode, all front panel switches except the local switch are disabled, and all front panel switch functions and various internal instrument functions are controlled by the host computer. Eight models are available (see Table 1).

Specifications

Motors:
Maximum of 12 stepper motors, 4 phase coil windings
Maximum ratings: 12 VDC @ 0.5A per phase.

Speed:
117,000 steps per second (maximum), depending on
the mechanical load and motor type.
Fully programmable automatic ramp-up and ramp-down.
Manual control with ergonomic knob on rotary pulse
generator (RPG) encoder.

Position Accuracy:
Within 1 step; absolute positioning depending upon
mechanical system.

GPIB Functions:
SH1 AH1 T6 L3 SR1 RL1 PP0 DC1 DT0 CO E1...XXX

Power Requirements:
85VAC through 264VAC universal (power supply),
48 to 62 Hz, single phase 550VA maximum
(NOTE: Fuse specified for 115VAC and 230VAC operation.)

Accessories Provided


1 ea. 499-C-082 115 VAC detachable power cord, or
1 ea. 499-C-469 'CE' certified 230 VAC detachable power cord.


Operating manual.


MT960C GPIB interconnect cable.

499-F-110 (6A, 5x20mm) time-lag fuse, or
1 ea. 499-F-107 (3A, 5x20mm) time-lag fuse.

Accessories Available (Not Provided)


MT960C GPIB interconnect cable assembly (one supplied with the MT986C controller).


MT982(x) tuner interface cable assembly (supplied with MT981, Mt982, and MT983 microwave tuner assemblies). One and two meter lengths available.


MT984(x) tuner interface cable assembly (supplied with MT984A01 microwave tuner assemblies). One and two meter lengths available.

MT979(x) tuner interface cable assembly (supplied with Mt984 microwave tuner assemblies). One and two meter lengths available.

MT999(x) tuner interface cable assembly (supplied with Mt999 microwave tuner assemblies). One and two meter lengths available.

MT986-4(xx) spare motor drive board assembly. One board required for each microwave tuner assembly (see Notes for Table 1.)

499-C-082 115 VAC detachable power cord assembly.

499-C-469 230 VAC 'CE' certified detachable power cord assembly.


MT986C

Dimensions

Front ViewSide View

Table 1. Available Models

MODEL NUMBER OF TUNERS COMPATIBLE TUNERS VOLTAGE
MT986C115A1 ONE ** (1 MOTOR BOARD) ALL MAURY MODELS 115VAC 50/60Hz
TWO * MT999
|MT986C230A1 ONE ** (1 MOTOR BOARD) ALL MAURY MODELS 230VAC 50/60Hz
TWO * MT999
MT986C115A2 TWO ** (2 MOTOR BOARD) ALL MAURY MODELS 115VAC 50/60Hz
FOUR * MT999
MT986C230A2 TWO ** (2 MOTOR BOARDS) ALL MAURY MODELS 230VAC 50/60Hz
FOUR * MT999
MT986C115A3 THREE ** (3 MOTOR BOARDS) ALL MAURY MODELS 115VAC 50/60Hz
FOUR * MT999
MT986C230A3 THREE ** (3 MOTOR BOARDS) ALL MAURY MODELS 230VAC 50/60Hz
FOUR * MT999
MT986C115A4 FOUR ** (4 MOTOR BOARDS) ALL MAURY MODELS 115VAC 50/60Hz
FOUR * MT999
MT986C230A4 FOUR ** (4 MOTOR BOARDS)
ALL MAURY MODELS 230VAC 50/60Hz
FOUR * MT999

Notes:
* The MT999 Harmonic Tuners require a split cable to run two MT999s from one of the four available Tuner Output Port on the MT986C Controller.

** Each Tuner Output Port requires one motor board. Four Tuner Output Ports require a total of four tuner motor boards. Each motor board can run a maximim of one standard microwave tuner and two MT999 harmonic tuners.
Copyright 2006 by Maury Microwave Corporation. All rights reserved.