Home
< Products
< Precision Calibration Standards <
Offset
Short Circuits
Offset
Short Circuits
Description The chart below lists the
available offset shorts. Those in rectangular guide are
nominally 1/8 and 3/8 wavelength offset at a frequency near
the waveguide band center. These will not be the exact band
center as the frequency is chosen to equalize the phase
differences at the band edges. Band
EIA Frequency
Range (GHz)
Model
Offset
(cm)
Delay Model
L
WR650
1.12
1.70
L340A1
3.581
119.488
L340A3
10.744
R
WR430
1.70
2.60
R340F1
2.336
77.946
R340F3
7.010
233.904
S
WR284
2.60
3.95
S340B1
1.524
50.852
S340B2
4.572
152.555
E
WR229
3.30
4.90
E340B3
1.359
45.346
E340B4
4.077
136.038
G
WR187
3.95
5.85
G340B1
1.212
40.441
G340B3
3.078
102.704
F
WR159
4.90
7.05
F340C1
0.815
27.194
F340C3
2.446
81.616
C
WR137
5.85
8.20
C340F1
0.686
22.890
C340F3
2.058
68.670
H
WR112
7.05
10.00
H340B1
0.571
19.067
H340B3
1.714
57.191
HS
WR102
7.00
11.00
HS340A
0.558
16.684
HS340B
1.676
55.923
X
WR90
8.20
12.40
X340B1
0.483
16.116
X340B3
1.448
48.316
M
WR75
10.00
15.00
M340C1
0.396
13.213
M340C3
1.189
39.674
P
WR62
12.40
18.00
P340A1
0.352
11.745
P340A2
1.055
35.202
N
WR51
15.00
22.00
N340A
0.267
8.909
N340B
0.800
26.694
K
WR42
18.00
26.50
K340A1
0.251
8.365
K340A2
0.752
25.095
U
WR28
26.50
40.00
U340B
0.150
5.005
U340C
0.450
15.015
J
WR22
33.00
50.00
J340A1
0.120
4.007
J340B1
0.360
12.022
V
WR15
50.00
75.00
V340A1
0.080
2.669
V340A3
0.240
8.008
Z
WR10
75.00
110.00
Z340A1
0.054
1.802
Z340A3
0.162
5.405
1Offset delay is calculated without consideration for the dispersive effect of waveguide, assuming the short is in air dielectric coaxial line. This follows the convention established for Agilent network analyzers. Anritsu analyzers use the actual mechanical offset in centimeters.
Offset shorts with
1/8 and 3/8 wavelength offsets are considered one of the
more accurate means of obtaining a 180 degrees phase
difference in waveguide. Use of these one-piece devices
reduces the number of flange interfaces during the
calibration and maintains the magnitude of the current flow
across the calibration plane essentially
constant.
Available Models
Waveguide
Size
(ps)1
(cm)
(ps)1