Waveguide
VNA Calibration Kits
< Optimized
Millimeter, 7005G Series
Optimized
Millimeter Waveguide VNA Calibration Kits
7005G
Series Optimized Kits Description The 7005G series high precision kits feature optimized standards and calibration constants, and are designed to provide highly accurate calibration of Agilent 8510A/B/C and Anritsu 360/37000 vector network analyzers for measurements in rectangular waveguide. Kits are available for the Agilent 8510 and Anritsu 360/37000 VNAs from 26.5 to 110 GHz (WR28 through WR10). See the Table 1 (below) for details. Flange
Information All kit component
flanges are provided with precision indexing holes for
excellent measurement repeatability (indexing pins are
provided with the kit). Kit components are provided in a
foam-lined wooden instrument case. Millimeter waveguide
flanges for use on WR22 and smaller sizes are of a unique
Maury pioneered design. This design features a raised outer
rim to prevent the flanges from cocking during connection,
and removable four-pin alignment pattern pins to permit
servicing the flanges. These flanges will mate with
corresponding UG( )/U flanges. Optimized
Directivity and Source Match The 7005G series VNA
calibration kits are configured for the
short-short-load-thru (SSLT) calibration method using offset
shorts and a sliding termination. The sliding termination
housings are calibrated for return loss and then selected
for compliance with directivity specification. The offset
shorts are calibrated and the calibration coefficients are
optimized for compliance with the source match
specification. The calibration data are provided in a
calibration report supplied with each kit. Since the
constants are optimized, the data medium supplied is unique
to each specific calibration kit. Test Port and Cable
Connectors These kits are
configured for use with VNAs utilizing external millimeter
waveguide test heads or modules. Kit Composition
As shown in the adjacent table, the 7005G model series calibration kits provide all the necessary devices for accurately calibrating the appropriate VNA. These kits are provided with a high precision sliding termination featuring a machined housing to ensure high effective directivity after calibration. The sliding terminations for use in WR22 waveguide and smaller sizes are equipped with a micrometer drive so that load positions can be easily and smoothly set. Precision straight sections and a fixed (reference plane) short are also provided and can be used as verification standards. Quantity Description Test port adapter Sliding termination, high precision Precision fixed termination Precision straight section High precision offset short, 1/8 wavelength High precision offset short, 3/8 wavelength Fixed (reference plane) short Flange tools (set) Flange hardware including indexing pins (set) Data medium containing the calibration constants 1 Instrument case Operating instructions Available Models
26.5 - 40.0
33.0 - 50.0
40.0 - 60.0
50.0 - 75.0
60.0 - 90.0
75.0 - 110.0 Table 2. To order a kit for your specific VNA include the option number from the table below where ( * ) is shown in Table 1 (above): 13 - Agilent 8510A/B 14 - Agilent 8510C 17 - 18 - Anritsu 360 19 - Anritsu 37000 1 Tape cartridge for the Agilent 8510A/B; 3-1/2" disk for the Agilent 8510C and Anritsu 360/37000 series.
![]()
Agilent 8510A/B/C
![]()
Anritsu 360
![]()
Anritsu 37000 series

Table 1.
(Minimum - dB)
(Minimum - dB)
Agilent E836x series PNA
Maury data sheet 3H-068.