Home < Products < Coaxial VNA Calibration Kits - Available Models < Type N TRL/LRL VNA Calbibration Kits - 8860 Series Tri-Kits

Type N TRL/LRL VNA Calibration Kits
8860 Series Tri-Kits

[Click on this image for a larger view.]


8860G14 - Type N TRL/LRL VNA Calibration Kit

Ordering Options
Toorder a kit configured to match your VNA model and specific application, add the apropriate option numbers (from Table 2) onto the end of the kit model number, as shown in Figure 1.

Figure 1. Model Number with Options Added.

Recommended Accessories
(Not Provided in Kits)
A020A Connector gage (push-on type)
A020D Connector gage thread-on type)
2698C1Torque wrench (12 in/lbs)

Features
TRL/LRL Calibrations
SOLT (Short-Open-Load-Thru)
Gated Air Line
Agilent VNAs
Type N connectors
DC to 18 GHz

Description
Thesetype N TRL/LRL calibration kits are designed for use with a range of Agilent Vector Network Analyzers (VNAs). The components in the kits are configured for use in making error-corrected TRL/LRL measurements of devices supplied with type N connectors, from DC to 18 GHz. With the components in these kits, users can perform three types of calibrations: 1) TRM, TRL and LRL two-port calibrations from 0 to 18 GHz; 2) SOLT (Short-Open-Load-Thru) one-port or two-port; and 3) Short-Open-(air line + load).1 one-port calibration for gated measurements. Source match can also be measured using the 15cm air line and provided short circuit.

Table 1. Equipment Provided in Kits.

Quantity
Description
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
Air line, 3.12cm
Air line, 3.82cm
Air line, 15cm
Offset short circuit, type N female
Offset short circuit, type N female
Offset short circuit, type N male
Open circuit, type N female
Open circuit, type N male
Fixed termination, type N female

Fixed termination, type N male

Calibration constants disk
Operating instructions
Instrument case

TRM/TRL/LRL Calibration
Table 2. shows the frequency ranges, calibration methods, and the
standards used to perform a complete 2-port calibration to 50 GHz.

Table 2. TRM/TRL/LRL Calibration.

Frequency Range
Type of Calibration
Calibration Standards
DC - 0.8 GHz
0.16 MHz - 0.8 GHz
0.8 GHz - 4.0 GHz
4.0 GHz - 18.0 GHz
TRM
TRL
TRL
LRL
Fixed Termination
15cm Air Line
3.12cm Air Line
3.12cm & 3.82cm Air Lines

Table 3. 3.5mm TRL/LRL VNA Calibration Kit Options.

TRL Adapter Options Network Analyzer Options
Option Description & Quantity
0 No Adapters
1
3.5mm female to type N female
3.5mm female to type N male
3.5mm male to type N female
3.5mm male to type N male
1 ea.
2
2.4mm female to type N female
2.4mm female to type N female
2.4mm male to type N female
2.4mm male to type N male
1 ea.
3
7mmmm to type N female
7mm to type N male
2.4mm male to type N female
2.4mm male to type N male
2 ea.
VNA Model Option
Agilent 8510A/B 3
Agilent 8510C 4
Agilent 8719/20/22 5
Agilent PNA E8360 series 7

1 Maury data sheet 2Z-051 explains these three types of calibrations.



Product Data Sheets and Application Notes (click the links below to download PDF* copies):

2Z-045 (73.7 KB) Technical Data - Model 8060 Series - 3.5mm TRL/LRL Calibration Kits
2Z-051 (73.4 KB) Technical Data - Model 7960 Series - 2.4mm TRL/LRL Calibration Kits
5E-062 (225.8 KB) Engineering Data - Precision 3.5mm (APC3.5) Coaxial connectors - Interface Dimensions

*PDF (Portable Document Format) files can be viewed with Adobe® Acrobat Reader™.
Download the PDF reader from Adobe.com
Request printed versions of Maury Product Data Sheets

Copyright 2006 by Maury Microwave Corporation. All rights reserved.