• Home < Precision Calibration Standards < Coaxial Calibration Kits < 8770C Series < Option Chart

    2.92mm (K) VNA Calibration Kits

    8780 Series

    Features
    Broad VNA Coverage
    0.04 to 40 GHz
    Includes Phase Matched Adapters
    Verified Kit Performance
    High Precision Female and male Sliding Terminations

    Description

    These precision K (2.92mm) connector calibration kits are designed for use with a broad range of Vector Network Analyzers (VNAs). With these kits, you can make error corrected measurements of devices equipped with K connectors from 40 MHz to 40 GHz.

    Each kit includes a full complement of calibration standards (shorts, opens, sliding and fixed loads) and can be configured to match any combination of VNA or test set and cable connectors. Ordering the 8770C with the appropriate option number from the Option Chart, allows you to tailor your kit to your specific application(s). All required calibration standards, adapters and accessories, plus the software (calibration constants and operating instructions) for your VNA, are supplied in an attractive foam-lined wooden instrument case. Each kit is tested for 100 percent compliance to kit specifications and is provided with a performance verification report.

    Connector Description

    The K connector is a precision miniature 2.92mm air line interface connector that operates mode free to 40 GHz. It has a mechanically compatible interface that mates with SMA and 3.5mm connectors. This interface was originally introduced by Maury in 1974 as MPC3 connector and was reintroduced as the K connector by Wiltron in 1984.

    Data Sheet 2Z-034C

    Software Media Provided

    VNA Model
    Media
    Agilent 8510A/B
    Cartridge
    Agilent 8510C
    3-1/2" disk
    Agilent 8719
    Agilent 8720
    Agilent 8722
    Agilent PNA Series
    Wiltron 360
    Wiltron 37000

    Calibration Kit Specifications

      Frequency Range. . . . . . . . . . . . . . . 0.040 - 40 GHz

      Directivity:
      0.042 - 20.0 GHz . . . . . . . . . . . . . . 42 dB minimum

      20.0 - 40.0 GHz . . . . . . . . . . . . . . . 40 dB minimum

      Source Match:
      0.042 - 20.0 GHz . . . . . . . . . . . . . . 40 dB minimum

      20.0 - 40.0 GHz . . . . . . . . . . . . . . . 35 dB minimum

      Nominal Impedance . . . . . . . . . . . . . . . . . . 50 ohms

    8770C 2.92mm (K) VNA Calibration Kit

    Equipment Provided in Kits

    1 ea. Fixed short, K female
    1 ea. Fixed short, K male
    1 ea. Open circuit, K female
    1 ea. Open circuit, K male
    1 ea. Precision fixed termination, K female
    1 ea. Precision fixed termination, K male
    1 ea. Precision sliding termination, K female
    1 ea. Precision sliding termination, K male
    1 ea. Open end wrench, 5/16
    1 ea. Open end wrench, 7/16
    1 ea. Torque wrench, 5/16, 8 in/lbs
    1 ea. Software configuration medium *
    1 ea. Adapter set *
    1 ea. Instrument case
    1 ea. Operating instructions
    * See adapter set listings

    Accessories Available (not provided)

    Connector Gages:

    a) Push-on type. . . . . . . . . . . . . . . . . . . . . A034B
    b) Thread-on type . . . . . . . . . . . . . . . . . . . A034E

    Adapter set Provided

    When the applicable option number is specified, one of the following adapter sets is provided:

    2.92mm adapter set, 8770Z1
    (supplied with options 13, 14, 15, 18 and 19)

  • 1 ea. Test port adapter, NMD2.92 female to K female
  • 1 ea. Test port adapter, NMD2.92 female to K male
  • 1 ea. Adapter, K female to female*
  • 1 ea. Adapter, K male to male*
  • 1 ea. Adapter, K female to male*

    * Phase matched set

    NOTE:

    The 8770Z1 adapter set will work with K (2.92mm) and 3.5mm test set/cable connectors.1

    7mm adapter set, 8770Z2
    (supplied with options 23, 24, 25, 28 and 29)

    1. 2 ea. Adapter, 7mm to female**
    2. 2 ea. Adapter, 7mm to K male**

    ** Phase matched set

  • 1 ea. Test port adapter, NMD2.4 female to K female
  • 1 ea. Test port adapter, NMD2.4 female to K male
  • 1 ea. Adapter, K female to 2.4mm female***
  • 1 ea. Adapter, K male to 2.4mm female***
  • 1 ea. Adapter, K female to 2.4mm male***
  • 1 ea. Adapter, K male to 2.4mm male***

    *** Phase matched set

  • Option Chart
    Select the option number appropriate for the VNA, test set and cable connectors to complete the model number.
    Example: Model 8770C34 is a K connector calibration kit for use on a Agilent 8510C with 2.4mm test set and cables.
    Test Port
    and
    Cable
    Connector
    Upper
    Frequency
    Limit Test
    (GHz)
    2
    VNA
    Agilent
    8510A/B


    Agilent
    8510C


    Agilent
    8719/20
    8722


    Anritsu
    360


    Anritsu 37200
    Adapter
    Set

    2.92mm (K)

    40.0

    N/A

    N/A

    N/A

    N/A

    N/A

    ****

    2.92mm (K)

    40.0

    03

    04

    05

    08

    09

    ****

    2.92mm (K)

    40.0

    13

    14

    15

    18

    19

    8770Z1

    3.5mm

    26.5

    13

    14

    15

    18

    19

    8770Z1 1

    7mm

    18.0

    23

    24

    25

    28

    29

    8770Z2

    2.4mm

    40.0

    33

    34

    35

    N/A

    N/A

    8770Z3

    N/A = No software in this kit.

    **** No adapter set include in these options.

    1

    K connectors (2.92mm) are mating compatible with 3.5mm. The resulting junction is calibrated out and is not critical.

    2

    Upper frequency limit is determined by the test set and cable connectors.

    Copyright 2006 by Maury Microwave Corporation. All rights reserved.