3.5mm TRL/LRL VNA Calibration Kits
8060A Series Tri-Kits
Features
 TRL/LRL Calibrations
 SOLT (Short-Open-Load-Thru)
 Gated Air Line
 Agilent VNAs
 3.5mm connectors
 DC to 34 GHz
Description
These 3.5mm TRL/LRL calibration kits are designed for use with a range of Agilent Vector Network Analyzers (VNAs). The components in the kits are configured for use in making error-corrected TRL/LRL measurements of devices supplied with 3.5mm connectors, from DC to 34 GHz.
TRM/TRL/LRL Calibration
Maury TRL/LRL calibration kits are tri-kits containing the components needed to perform three types of calibrations (TRM/TRL/LRL, SOLT and short-open-(air line +load).1 Source match can also be measured using the 6.25cm air line and provided short circuit.
Table 1. Equipment Provided in Kits.
| Quantity |
Description
|
|
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
2 ea.
1 ea.
1 ea.
1 ea.
|
Air line, 3.5mm female to male, 15cm
Air line, 3.5mm female to male, 5cm
Air line, 3.5mm female to male, 6cm
Air line, 3.5mm female to male, 5.3cm
Fixed short, 3.5mm female
Fixed short, 3.5mm male
Open circuit, 3.5mm female
Open circuit, 3.5mm male
Fixed termination, 3.5mm female
Fixed termination, 3.5mm male
Double end wrenches, 5/16-inch
Calibration constants disk
Operating instructions
Instrument case
|
TRM/TRL/LRL Calibration
Table 2. shows the frequency ranges, calibration methods, and the
standards used to perform a complete 2-port calibration to 50 GHz.
Table 2. TRM/TRL/LRL Calibration.
| Frequency Range |
Type of Calibration
|
Calibration Standards |
|
DC - 800 MHz
160 MHz - 800 MHz
800 MHz - 2.5 GHz
2.5 GHz - 12.5 GHz
12.5 GHz - 34.0 GHz
|
TRM
TRL
TRL
LRL
LRL
|
Fixed Termination
15cm Air Line
5cm Air Line
5cm & 6cm Air Lines
5cm & 5.3cm Air Lines
|
Table 3. 3.5mm TRL/LRL VNA Calibration Kit Options.
| TRL Adapter Options |
Network Analyzer Options |
| Option |
Description & Quantity |
|
1
|
3.5mm female to 3.5mm female
3.5mm male to 3.5mm male
3.5mm female to 3.5mm male |
1ea.
|
|
| 2 |
2.4mm female to 3.5mm female
2.4mm female to 3.5mm male
2.4mm male to 3.5mm female
2.4mm male to 2.4mm male
2.4mm male to 3.5mm male |
1ea.
|
|
|
| VNA Model |
Option |
| Agilent 8510A/B |
3 |
| Agilent 8510C |
4 |
| Agilent 8719/20/22 |
5 |
| Agilent PNA E8360 series |
6 |
|
1 Maury data sheet 2Z-051 explains these three types of calibrations.
Product Data Sheets and Application Notes (click the links below to download PDF* copies):
 2Z-045 (73.7 KB)  Technical Data - Model 8060 Series - 3.5mm TRL/LRL Calibration Kits
 2Z-051 (73.4 KB)  Technical Data - Model 7960 Series - 2.4mm TRL/LRL Calibration Kits
 5E-062 (225.8 KB)  Engineering Data - Precision 3.5mm (APC3.5) Coaxial connectors - Interface Dimensions
*PDF (Portable Document Format) files can be viewed with Adobe® Acrobat Reader.
 Download the PDF reader from Adobe.com
 Request printed versions of Maury Product Data Sheets
|