Home < Products < Coaxial VNA Calibration Kits - Available Models < 2.4mm TRL/LRL VNA Calbibration Kits - 7960A Series

2.4mm TRL/LRL VNA Calibration Kits
7960A Series Tri-Kits

Features
TRL/LRL Calibrations
SOLT (Short-Open-Load-Thru)
Gated Air Line
DC to 50 GHz
Agilent VNAs

Description

These 2.4mm calibration kits are designed for use with a range of Vector Network Analyzers (VNAs). the components in the kits are configured for use in making error-corrected TRL/LRL measurements of devices supplied with 2.4mm connectors1, from DC to 50 GHz.

Calibration Types

Maury TRL/LRL calibration kits are tri-kits containing the components needed to perform three types of calibrations (TRM/TRL/LRL, SOLT and short-open-(air line +load).1 Source match can also be measured using the 6.25cm air line and provided short circuit.

Table 1. Equipment Provided in Kits.

Quantity
Description
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
2 ea.
1 ea.
1 ea.
1 ea.
Air line, 2.4mm female to male, 1.25cm
Air line, 2.4mm female to male, 1.5cm
Air line, 2.4mm female to male, 6.25cm
Fixed short, 2.4mm female
Fixed short, 2.4mm male
Open circuit, 2.4mm female
Open circuit, 2.4mm male
Fixed termination, 2.4mm female

Fixed termination, 2.4mm male

Open end wrenches, 5/16-inch
Calibration constants disk
Operating instructions
Instrument case

Recommended Accessories (Not Provided in Kits)
A035E Connector gage (thread-on type)
8799A1Torque wrench (8 in/lbs)

TRM/TRL/LRL Calibration

Table 2. shows the frequency ranges, calibration methods, and the standards used to perform a complete 2-port calibration to 50 GHz.

Table 2. TRM/TRL/LRL Calibration.

Frequency Range
Type of Calibration
Calibration Standards
DC - 400 MHz
400 MHz - 2.0 GHz

2.0 GHz - 10.0 GHz
10.0 GHz - 50.0 GHz
TRM
TRL
TRL
LRL
Fixed Term.
6.25cm Air Line
1.25cm Air Line
1.25cm & 1.5cm Air Lines

1 Maury data sheet 2Z-051 explains these three types of calibrations, with complete specifications for the components listed on this page.

[Click on this image for a larger view.]


7960A - 2.4mm TRL/LRL VNA Calibration Kit

Ordering Options
Toorder a kit configured to match your VNA model and specific application, add the apropriate option numbers (from Table 3) onto the end of the kit model number, as shown in Figure 1.

Figure 1. Model Number with Options Added.

Table 3. 2.4mm TRL/LRL VNA Calibration Kit Options.

TRL Adapter Options Network Analyzer Options
Option Description & Quantity
1
NMD2.4mm(f) to 2.4mm female
NMD2.4mm(f) to 2.4mm male
2.4mm female to 2.4mm female
2.4mm male to 2.4mm male
2.4mm female to 2.4mm male
1ea.
2
NMD2.92mm(f) to 2.4mm female
NMD2.92mm(f) to 2.4mm male
2.4mm female to 2.4mm female
2.4mm male to 2.4mm male
2.4mm female to 2.4mm male
1ea.
VNA Model Option
Agilent 8510A/B 3
Agilent 8510C 4
Agilent 8719/20/22 5
Agilent PNA E8360 series 6


Product Data Sheets and Application Notes (click the links below to download PDF* copies):

2Z-051 (79.6 KB) Technical Data - Model 7960A Series - 2.4mm TRL/LRL VNA Calibration Kits
5E-064 (50.1 KB) Engineering Data - Precision 2.4mm (GPC2.4) Coaxial connectors - Interface Dimensions

*PDF (Portable Document Format) files can be viewed with Adobe® Acrobat Reader™.
Download the PDF reader from Adobe.com
Request printed versions of Maury Product Data Sheets

Copyright 2006 by Maury Microwave Corporation. All rights reserved.