2.4mm TRL/LRL VNA Calibration Kits
7960A Series Tri-Kits
Features
 TRL/LRL Calibrations
 SOLT (Short-Open-Load-Thru)
 Gated Air Line
 DC to 50 GHz
 Agilent VNAs
Description
These 2.4mm calibration kits are designed for use with a range of Vector Network Analyzers (VNAs). the components in the kits are configured for use in making error-corrected TRL/LRL measurements of devices supplied with 2.4mm connectors1, from DC to 50 GHz.
Calibration Types
Maury TRL/LRL calibration kits are tri-kits containing the components needed to perform three types of calibrations (TRM/TRL/LRL, SOLT and short-open-(air line +load).1 Source match can also be measured using the 6.25cm air line and provided short circuit.
Table 1. Equipment Provided in Kits.
| Quantity |
Description
|
|
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
1 ea.
2 ea.
1 ea.
1 ea.
1 ea.
|
Air line, 2.4mm female to male, 1.25cm
Air line, 2.4mm female to male, 1.5cm
Air line, 2.4mm female to male, 6.25cm
Fixed short, 2.4mm female
Fixed short, 2.4mm male
Open circuit, 2.4mm female
Open circuit, 2.4mm male
Fixed termination, 2.4mm female
Fixed termination, 2.4mm male
Open end wrenches, 5/16-inch
Calibration constants disk
Operating instructions
Instrument case
|
Recommended Accessories (Not Provided in Kits)
A035E Connector gage (thread-on type)
8799A1 Torque wrench (8 in/lbs)
TRM/TRL/LRL Calibration
Table 2. shows the frequency ranges, calibration methods, and the standards used to perform a complete 2-port calibration to 50 GHz.
Table 2. TRM/TRL/LRL Calibration.
| Frequency Range |
Type of Calibration
|
Calibration Standards |
|
DC - 400 MHz
400 MHz - 2.0 GHz
2.0 GHz - 10.0 GHz
10.0 GHz - 50.0 GHz
|
TRM
TRL
TRL
LRL
|
Fixed Term.
6.25cm Air Line
1.25cm Air Line
1.25cm & 1.5cm Air Lines
|
1 Maury data sheet 2Z-051 explains these three types of calibrations, with complete specifications for the components listed on this page.
|
[Click on this image for a larger view.]

7960A - 2.4mm TRL/LRL VNA Calibration Kit
|
Ordering Options
To order a kit configured to match your VNA model and specific application, add the apropriate option numbers (from Table 3) onto the end of the kit model number, as shown in Figure 1.
Figure 1. Model Number with Options Added.

|
|
Table 3. 2.4mm TRL/LRL VNA Calibration Kit Options.
| TRL Adapter Options |
Network Analyzer Options |
| Option |
Description & Quantity |
|
1
|
NMD2.4mm(f) to 2.4mm female
NMD2.4mm(f) to 2.4mm male
2.4mm female to 2.4mm female
2.4mm male to 2.4mm male
2.4mm female to 2.4mm male |
1ea.
|
|
| 2 |
NMD2.92mm(f) to 2.4mm female
NMD2.92mm(f) to 2.4mm male
2.4mm female to 2.4mm female
2.4mm male to 2.4mm male
2.4mm female to 2.4mm male |
1ea.
|
|
|
| VNA Model |
Option |
| Agilent 8510A/B |
3 |
| Agilent 8510C |
4 |
| Agilent 8719/20/22 |
5 |
| Agilent PNA E8360 series |
6 |
|
|
|