Home
< Precision
Calibration Standards
< Coaxial
Calibration Kits
< 2450
Series
14mm
(MPC14) VNA Calibration Kits
2450
Series These coaxial VNA calibrtion
kits are configured for the Open-Short-Load-Thru (OSLT)
calibration technique using sliding loads. Features Description Each kit includes a full
complement of calibration standards and accessories (listed
below), and the software (3-1/2" disk or cartridge) needed
to easily load the calibration constants into your
VNA. Connector
Description Model
Chart Model
VNA
Test Set and
Cable Software
Medium
2450F
Agilent
8510A/B
2450F14
Agilent
8510C
2450F26
Agilent
8753C/D
2450W
Anritsu 360
2450W20
Anritsu 360
2450X
Anritsu
37000
2450X20
Anritsu
37000
Options:
01
Adds one (1) 2453A
30cm Reference Air Line.
20
Replaces the NMD
and 3.5mm-to-7mm adapters 21
Combines Option 01
and Option 20.
Equipment
Provided In Each Kit 1 ea.
Fixed Short,
14mm
1 ea.
Open Circuit,
14mm
2 ea.
Fixed Termination,
14mm
1 ea.
Sliding
Termination, 14mm
1 ea.
Adapter, 14mm to
3.5mm (female)
1 ea.
Adapter, 14mm to
3.5mm (male)
1 ea.
Adapter, 14mm to
NMD3.5mm (female)
1 ea.
Connector Gage Kit,
14mm (push-on type)
1 ea.
Torque Wrench, 1.00
hex, 12 in/lb
1 ea.
Configuration
Cartridge (or disk)
1 ea.
Contact
Installation/Extraction Tool
2 ea.
14mm Contacts
(Spare Parts)
1 ea.
Instrument
Case
1 ea.
Operating
Instructions
Available
Accessories Offset
Shorts
Series 2449 can be
used as verification or calibration
standards.
Precision
Mismatches
Series 2411 are
resistive mismatches (DC to 8.5 GHz) in values up
to 2:1 VSWR
Precision Two-Port
Standard Set
Model 2454
1
The 3.5mm female (NMD3.5f) connector on the 14mm adapter mates directly with the NMD3.5m connector on Agiletn 8513A, 8514B, 2
An external disk drive is
needed to use the 3-1/2" disk with the agilent 8753C.
constants may also be manually keyed-in.
Data Sheet 2Z-021C
Expanded
Kits
Connector Gage
Torque Wrench
Test Port Adapters
These kits are
designed for use with vector network analyzers (VNAs) that
have 3.5mm, 2.92mm or 7mm test set connectors and cables,
and are used to make error corrected measurements of devices
with 14mm connectors from 45 MHz to 8.5 GHz.
The MPC14 precision
14mm connector is essentially equivalent to, and mating
compatibile with, GR900 type connectors. It features an
improved center conductor inner contact (model 2481A) and an
improved hex knurl coupling nut (which has a 1.00 inch hex
for accurate torque wrench tightening and a knurled knob for
easier finger tightening).
Select the
calibration kit number appropriate for your VNA test set and
cable connector.
Connectors
with two (2) 14mm-to-7mm adapters (2607A1)

2450W01
(Not Provided)
and 8515A test sets, and the male K connector on Anritsu VNAs.